11Extra-low voltage — IEC voltage range AC DC defining risk High voltage (supply system) > 1000 Vrms > 1500 V electrical arcing Low voltage (supply system) 25–1000 Vrms 60–1500 V electrical shock Extra low voltage (supply system) < 25 V …
12Quantum point contact — A Quantum Point Contact (QPC) is a narrow constriction between two wide electrically conducting regions, of a width comparable to the electronic wavelength (nano to micrometer). Quantum point contacts were first reported in 1988 by a Dutch group… …
13High-voltage direct current — HVDC or high voltage, direct current electric power transmission systems contrast with the more common alternating current systems as a means for the bulk transmission of electrical power. The modern form of HVDC transmission uses technology… …
14Scanning voltage microscopy — (SVM) sometimes also called nanopotentiometry is a scientific experimental technique based on atomic force microscopy. A conductive probe, usually only a few nanometers wide at the tip, is placed in full contact with an operational electronic or… …
15Ohmic contact — An ohmic contact is a region on a semiconductor device that has been prepared so that the current voltage (I V) curve of the device is linear and symmetric. If the I V characteristic is non linear and asymmetric, the contact is not ohmic, but is… …
16Point-contact transistor — A point contact transistor was the first type of solid state electronic transistor ever constructed. It was made by researchers John Bardeen and Walter Houser Brattain at Bell Laboratories in December of 1947. They were working with physicist… …
17Dry contact — may mean any of the following in electronics: No current: Dry contact can refer to a secondary set of contacts of a relay circuit which does not make or break the primary current being controlled by the relay. Usually some other contacts or… …
18Test light — Neon test lamp for line voltages A test light, test lamp, voltage tester, or mains tester is a very simple piece of electronic test equipment used to determine the presence or absence of an electric voltage in a piece of equipment under test.… …
19ГОСТ Р 50030.5.4-2011: Аппаратура распределения и управления низковольтная. Часть 5.4. Аппараты и элементы коммутации для цепей управления. Метод оценки рабочих характеристик слаботочных контактов. Специальные испытания — Терминология ГОСТ Р 50030.5.4 2011: Аппаратура распределения и управления низковольтная. Часть 5.4. Аппараты и элементы коммутации для цепей управления. Метод оценки рабочих характеристик слаботочных контактов. Специальные испытания оригинал… …
Словарь-справочник терминов нормативно-технической документации
20ГОСТ Р МЭК 61557-1-2005: Сети электрические распределительные низковольтные напряжением до 1000 В переменного тока и 1500 В постоянного тока. Электробезопасность. Аппаратура для испытания, измерения или контроля средств защиты. Часть 1. Общие требования — Терминология ГОСТ Р МЭК 61557 1 2005: Сети электрические распределительные низковольтные напряжением до 1000 В переменного тока и 1500 В постоянного тока. Электробезопасность. Аппаратура для испытания, измерения или контроля средств защиты. Часть …
Словарь-справочник терминов нормативно-технической документации