- phase-fault current
-
ток замыкания между фазами (без земли)
Англо-русский словарь технических терминов. 2005.
Англо-русский словарь технических терминов. 2005.
Fault current — A fault current is an abnormal current in an electric circuit due to a fault (usually a short circuit or abnormally low impedance path).In terms of installation wiring, the prospective short circuit current must be known as it influences the… … Wikipedia
Fault (power engineering) — A fault is any abnormal situation in an electrical system in which the electrical current may or may not flow through the intended part/s.Fault is a condition when the current or voltage in any circuit do not flow in the same phase. in other… … Wikipedia
Fault indicator — A fault indicator is a device which provides visual indication of an electrical fault. They are used in electric power distribution networks as a means of automatically detecting and identifying faults. Basic principles During an electrical fault … Wikipedia
Current sea level rise — This article is about the current and future rise in sea level associated with global warming. For sea level changes in Earth s history, see Sea level#Changes through geologic time. Sea level measurements from 23 long tide gauge records in… … Wikipedia
Residual-current device — A two pole residual current device A Residual Current Device is a generic term covering both RCCBs and RCBOs. A Residual Current Circuit Breaker (RCCB) is an electrical wiring device that disconnects a circuit whenever it detects that the… … Wikipedia
Alternating current — (green curve). The horizontal axis measures time; the vertical, current or voltage. In alternating current (AC, also ac) the movement of electric charge periodically reverses direction. In direct current (DC, also dc), the flow of electric charge … Wikipedia
Split-phase electric power — A split phase electricity distribution system is a 3 wire single phase distribution system, commonly used in North America for single family residential and light commercial (up to about 100 kVA) applications. It is the AC equivalent of the… … Wikipedia
High-voltage direct current — HVDC or high voltage, direct current electric power transmission systems contrast with the more common alternating current systems as a means for the bulk transmission of electrical power. The modern form of HVDC transmission uses technology… … Wikipedia
Isolated-phase bus — In electrical engineering, isolated phase bus is a method of construction for circuits carrying very large currents, typically between a generator and its step up transformer in a steam or large hydroelectric power plant.Each phase current is… … Wikipedia
Single-phase electric power — In electrical engineering, single phase electric power refers to the distribution of alternating current electric power using a system in which all the voltages of the supply vary in unison. Single phase distribution is used when loads are mostly … Wikipedia
San Andreas Fault Observatory at Depth — The San Andreas Fault Observatory at Depth (SAFOD) is one of three components of the Earthscope Project, funded by the National Science Foundation in conjunction with the USGS and NASA. The SAFOD site is located just north of the town of… … Wikipedia