- zero-sequence component
- составляющая нулевой последовательности фаз
Большой англо-русский и русско-английский словарь. 2001.
Большой англо-русский и русско-английский словарь. 2001.
zero sequence component — nulinės sekos dedamoji statusas T sritis automatika atitikmenys: angl. zero sequence component vok. Nullkomponente, f rus. составляющая нулевой последовательности, f pranc. composante de séquence zéro, f; composante homo polaire, f … Automatikos terminų žodynas
composante de séquence zéro — nulinės sekos dedamoji statusas T sritis automatika atitikmenys: angl. zero sequence component vok. Nullkomponente, f rus. составляющая нулевой последовательности, f pranc. composante de séquence zéro, f; composante homo polaire, f … Automatikos terminų žodynas
Component Object Model — Not to be confused with COM file. Component Object Model (COM) is a binary interface standard for software componentry introduced by Microsoft in 1993. It is used to enable interprocess communication and dynamic object creation in a large range… … Wikipedia
Zero (Mega Man) — General CVG character name=Zero caption=Zero as he appears in the Mega Man X and Mega Man Zero series. firstgame= Mega Man X series= Mega Man X series and Mega Man Zero series creator=Keiji Inafune voiceactor=Wayne Doster (1997 2002) Jack… … Wikipedia
Parity of zero — Zero objects, divided into two equal groups Zero is an even number. In other words, its parity the quality of an integer being even or odd is even. Zero fits the definition of even number : it is an integer multiple of 2, namely 0 × 2. As a… … Wikipedia
Evenness of zero — The number 0 is even. There are several ways to determine whether an integer is even or odd, all of which indicate that 0 is an even number: it is a multiple of 2, it is evenly divisible by 2, it is surrounded on both sides by odd integers, and… … Wikipedia
Myelin protein zero — PDB rendering based on 1neu … Wikipedia
Asymmetric fault — In power engineering, specifically three phase power, an asymmetric or unbalanced fault is a fault which does not affect each of the three phases equally. This is in contrast to a symmetric fault, where each of the phases is affected equally. In… … Wikipedia
Gegensystem — In der Elektrotechnik wird die Methode der Symmetrischen Komponenten benutzt, um eine vereinfachte Analyse eines unbalancierten Fehlers in einem Drehstromsystem (Dreiphasen Wechselstromsystem) vorzunehmen. Dabei wird ein unsymmetrisches System… … Deutsch Wikipedia
Mitsystem — In der Elektrotechnik wird die Methode der Symmetrischen Komponenten benutzt, um eine vereinfachte Analyse eines unbalancierten Fehlers in einem Drehstromsystem (Dreiphasen Wechselstromsystem) vorzunehmen. Dabei wird ein unsymmetrisches System… … Deutsch Wikipedia
Symmetrische Komponenten — In der Elektrotechnik wird die Methode der Symmetrischen Komponenten benutzt, um eine vereinfachte Analyse eines unbalancierten Fehlers in einem Drehstromsystem (Dreiphasen Wechselstromsystem) vorzunehmen. Dabei wird ein unsymmetrisches System… … Deutsch Wikipedia